Model Number: 417-A01 RC-112E
Key Specifications/Special Features:
Product introduction:Product adopts the latest electronic technique with LED display, which learn from theadvantages and experience of stand-alone edition temperature controllers domesticallyand overseasMost economical product with simple operation, stable performance, small size and intelligent control, cool and heat shift functions, which applies to variousrefrigeration and heating places and equipmentsParameters:Temperature measure range: - 40 to 99°CResolution: 1°C
Accuracy: ±1°C
Power supply: 220V AC ±10%, 50/60Hz
Input: one NTC sensor
Output: one relay 10A/220V AC
Ambient requirements:
Temperature: -10 to 60°C
Humidity: 20 to 85% (no condensate)
Cut-out size: 71x29mm
Consumption: ≤3W
Relay 10A: resistive load maximum 1100W, inductive load maximum 275W and incandescent bulb maximum 220W
Function description:
Temperature calibration
When there is difference between the measuring temperature and the standard temperature, this function can keep the measuring temperature same as the standard temperature
Temperature after calibration= temperature before calibration + adjusted value
Cool and heat function:
In cool mode:
Cooling systems works in below situation:
Measuring temperature ≥ set temperature + Temperature differential
Cooling systems stop working in below situation:
Measuring temperature ≤ set temperature
In heat mode:
Heating systems works in below situation:
Measuring temperature ≤ set temperature the temperature difference
Heating systems stop working in below situation:
Measuring temperature ≥ set temperature
Delay time:
When power on for the first time, if the measuring temperature ≥ set temperature + temperature differential or measuring temperature ≤ set temperature difference, the output will not be activated immediately, and will be activated after delay time
Time period between the previous stop and this starts is longer than the delay time
Installation notes:
Output will be activated immediately, if it is shorter than the delay time, the output will be
activated after the delay time
Delay time is calculated from the previous output stop